Open
Description
Hello all,
I'm reading in a few neuralynx datasets, and something I've been coming across is a value error when parsing the header. At first I thought it had to with simultaneous EEG and SU recordings (where EEG is at 5K sample rate, and microLFP at 32K). Upon further investigation, I think it has to do with segments (EEG files have 55 segments, and microLFP files have 57 segments). Is there any way to get past this easily? I see an exclude parameter in the class, but does this accept a list of filenames so I can generate two IO classes (one EEG and one microLFP)?